TM 5-2420-231-23-1
0031
Table 1. Heating, Ventilation, and A/C (HVAC) Blower Motor Does Not
Operate at One or More Speeds - Continued.
031
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
HVAC Blower Motor Does
continuity between front console
Not Operate at One or More
options wiring harness (WP 0163).
options wiring harness connector
Speeds - Continued
Install blower fan switch (WP 0172).
Connect side options wiring harness
and machine ground. There should
be no continuity.
Install rear instrument panel right-side
cover (WP 0176).
Install new blower fuse (TM 5-2420-
231-10).
Proceed to Test Step 14.
Test Step 14. Verify That Symptom Is
Resolved.
1. Connect all wiring harness con-
nectors.
2. Connect batteries (WP 0157).
3. Turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
4. Turn blower fan switch (Figure 10,
HVAC Blower Motor Operates at
Each Speed Setting - Proceed to step
Item 1) to each speed setting (TM
5.
5-2420-231-10) and verify that
HVAC blower motor turns on.
HVAC Blower Motor Does Not
Operate at One or More Speeds -
Repeat troubleshooting from the
beginning.
0031-20