Table 1. Return-to-Dig Function Fails to Operate or Operates Improperly - Continued.
Table 1. Return-to-Dig Function Fails to Operate or Operates Improperly - Continued.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  924    925    926    927    928  929  930    931    932    933    934  
img
. .
TM 5-2420-231-23-1
0070
Table 1. Return-to-Dig Function Fails to Operate or Operates Improperly - Continued.
070
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. Turn ignition switch to on position
Return-to-Dig Function Fails
(TM 5-2420-231-10).
to Operate or Operates
Improperly - Continued
6. Using digital multimeter, test for
Voltage 10 to 14 Volts - Proceed to
voltage between front main chas-
step 7.
sis wiring harness connector termi-
Voltage Less Than 10 Volts - Replace
nal 2 (WP 0007, Figure 226) and
main chassis wiring harness (WP
ground. Voltage should be 10 to 14
0154).
volts.
Proceed to Test Step 9.
7. Using digital multimeter, test for
Voltage 10 to 14 Volts - Replace
voltage between front main chas-
return-to-dig solenoid (WP 0262).
sis wiring harness connector termi-
Proceed to Test Step 9.
nal 2 and terminal 1 (WP 0007,
Voltage Less Than 10 Volts - Proceed
Figure 226). Voltage should be 10
to Test Step 6.
to 14 volts.
0070-5