TM 5-2420-231-23-1
0070
Table 1. Return-to-Dig Function Fails to Operate or Operates Improperly - Continued.
070
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. Turn ignition switch to on position
Return-to-Dig Function Fails
(TM 5-2420-231-10).
to Operate or Operates
Improperly - Continued
Voltage 10 to 14 Volts - Proceed to
voltage between front main chas-
step 7.
sis wiring harness connector termi-
Voltage Less Than 10 Volts - Replace
main chassis wiring harness (WP
ground. Voltage should be 10 to 14
0154).
volts.
Proceed to Test Step 9.
Voltage 10 to 14 Volts - Replace
voltage between front main chas-
sis wiring harness connector termi-
Proceed to Test Step 9.
Voltage Less Than 10 Volts - Proceed
Figure 226). Voltage should be 10
to Test Step 6.
to 14 volts.
0070-5