Table 1. Left Stabilizer Does Not Operate Correctly - Continued.
078
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 14. Test for Shorted Pilot
Left Stabilizer Does Not
Control Wiring Harness to Left-Hand
Operate Correctly -
Continued
1. Disconnect pilot control wiring har-
179) from left-hand stabilizer up
continuity between pilot control
wiring harness (WP 0187).
wiring harness connector (WP
Proceed to Test Step 16.
0007, Figure 179) terminals 1 and
2. There should be no continuity.
15.
Test Step 15. Test for Open Pilot
Control Wiring Harness to Left-Hand
1. Install a jumper wire between pilot
control wiring harness connector
and 2.
Resistance 5.0 Ohms or Less -
sure resistance between pilot con-
Replace backhoe pilot control controller
trol wiring harness connector (WP
(WP 0191).
0007, Figure 179) terminals 1 and
Remove jumper wire from pilot control
or less.
Figure 160) terminals 2 and 3.
Connect all wiring harness connectors.
Proceed to Test Step 16.
Replace pilot controls wiring harness
(WP 0187).
Proceed to Test Step 16.
Test Step 16. Verify That Symptom Is
Resolved.
1. Ensure all wiring harness connec-
tors are connected.
2. Start and operate machine (TM 5-
2420-231-10).
3. Turn pilot control switch to the on
position (TM 5-2420-231-10).
4. Wait 2 seconds before operation.
0078-9