Figure 4. Instrument Panel.
OPERATOR CONTROLS - Continued

Maintenance Manual For Loader, Scoop Type, Ded 4 X 4, Articulated Frame Steer, 4.5 To 5 Cu. Yd.
Page Navigation
  50    51    52    53    54  55  56    57    58    59    60  
img
TM 5-3805-255-14
0004
OPERATOR CONTROLS CONTINUED
Figure 5. Instrument Panel.
04
KEY
COMPONENT OR INDICATOR
DESCRIPTION
04
04
04
5
Engine Oil Pressure Gauge
This gauge shows the pressure at which the lubricating
oil is circulating through the engine. This gauge must
register in the "IDLE" range immediately upon starting.
When engine is operated at full load speed, pointer
must be in (green) "RUN" range. Stop engine
immediately and investigate cause if little or no pressure
is indicated.
6
Starter Switch
CAUTION
Never  press  starter  switch
while engine is running. This
will damage starter and engine
flywheel.
Turn the combination switch to ignition position and
press starter switch to crank engine. After engine starts
to run release starter switch.
7
Engine Coolant Temperature
This gauge shows temperature of coolant circulating
Gauge
through engine. After engine has operated a sufficient
length of time pointer of gauge must be in (green)
"RUN" range.