TM 5-3805-255-14
0061
REMOVAL CONTINUED
Right Treadle Valve
00061
1. Disconnect hoses (Figure 4, Items 2 and 3) from check valve (Figure 16, Item 1).
2. Remove right check valve (Figure 4, Item 1) from fitting (Figure 16, Item 14).
3. Disconnect tube (Figure 4, Item 4) from elbow (Figure 16, Item 5).
4. Disconnect hoses (Figure 4, Items 8 and 10) from elbows (Figure 16, Items 9 and 11).
5. Disconnect hose (Figure 4, Item 7) from elbow (Figure 16, Item 6).
6. Disconnect tube (Figure 4, Item 13) from fitting (Figure 16, Item 12).
7. Remove elbows (Figure 4, Items 5, 6, and 9) from treadle valve (Figure 16, Item 15).
8. Remove fittings (Figure 4, Items 12 and 14) from treadle valve (Figure 16, Item 15).
9. Remove three bolts (Figure 4, Item 16), nuts (Figure 4, Item 17), lockwashers (Figure 4, Item 18), and treadle
valve (Figure 4, Item 15) from floorboard (Figure 4, Item 19). Discard lockwashers.
H100C-0902
Figure 4. Right Treadle Valve.
0061
END OF TASK
0061-5