TM 5-3805-255-14
0062
CLEANING AND INSPECTION
00062
1. Clean and inspect all parts IAW General Maintenance Instructions (WP 0019).
2. Clean exterior and interior of reservoir with hot water and steam. Inspect exterior of reservoir for damage or
corrosion. Replace damaged reservoir. Keep exterior of reservoir painted to retard corrosion.
END OF TASK
INSTALLATION
00062
1. Install reservoir (Figure 3, Item 5), two U-bolts (Figure 3, Item 3), and four nuts (Figure 3, Item 4) on frame
(Figure 3, Item 10).
2. Connect air tubes (Figure 3, Items 1 and 2) to reservoir (Figure 3, Item 5).
3. Connect air drain tubes (Figure 3, Items 8 and 9) to bottom of reservoir (Figure 3, Item 5).
4. Connect air tubes (Figure 3, Items 6 and 7) to right side of reservoir (Figure 3, Item 5).
Figure 3. Reservoir (Right Side).
062
0062-4