TM 5-3805-262-10
2-1. INSTRUMENT PANELS (CONT)
a. Right Instrument Panel (Cont).
(5) Other Controls and Indicator.
SHUT OFF CONTROL
Fuel shut off control; engine stop.
Cable connected to fuel injection
pump fuel shut off lever.
Pull out to stop engine. After en-
gine has stopped, push control in.
Control must be pushed in all the
way in order to start engine.
PARKING BRAKE CONTROL
Pull on, push off control.
Applies parking brake.
Pulling knob out applies parking
brake.
Pushing knob in releases
parking brake. When parking brake
applied, BRAKE ENGAGED and CLUTCH
PRESS warning indicators on left in-
strument panel will be lit.
DIMMER COMPT LIGHTS CONTROL
Rheostat control.
Controls brightness of gage lights
and cab dome light (auxiliary switch
in any position other than OFF).
Turn control to extreme counter-
clockwise position for brightly lit
lights. Turn control clockwise to
decrease brightness. Extreme clock-
wise position turns lights off.
AIR PRESSURE WARNING ALARM
Audible alarm.
Sounds when engine is first started
until air pressure reaches approxi-
mately 65 psi at which time it will
turn off. During operation, sounds
to warn operator that there is not
enough air pressure to continue op-
erating loader safely.
2-6