TM 5-3805-262-20INSTALLATION(1)(2)(3)( 4)(5)TESTING(1)(2)(3)( 4)Install thermostats (4) in water manifold as shown.Position new gasket (5) on watermanifold.Position thermostat housing (3) andsecure using three lock washers (2)and capscrews (l). Tighten capscrewsto 35 to 42 lb - ft.Connect radiator upper radiator hoseto thermostat housing (3) (page4 - 7 5 ) .Fill radiator with coolant (page4-71) and check for coolant leaks.Immerse thermometer (4) in quart container containing hot water heated toapproximately 175 degrees and thermometer as shown.Thermostat should begin to open between 175 to185 degrees F and be completely open at 202degrees F. Replace thermostat if it does not meett h e s e s p e c i f i c a t i o n s.Remove thermostat (4) from container and dryusing clean dry cloth.Repeat steps (1) through (3) above for remainingt h e r m o s t a t.4-89