TM 5-3805-262-20
CLEANING AND INSPECTION
Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.
W e a r p r o t e c t i v e g o g g l e s a n d g l o v e s a n d u s e o n l y i n a w e l l v e n t i l a t e d
a r e a . A v o i d c o n t a c t w i t h s k i n,
e y e s a n d c l o t h e s a n d d o n - t b r e a t h e
vapors. Do not use near open flame or excessive heat and dont smoke
w h e n u s i n g i t . F a i l u r e t o d o s o c o u l d c a u s e s e r i o u s i n j u r y . I f y o u
b e c o m e d i z z y w h i l e u s i n g c l e a n i n g s o l v e n t , g e t f r e s h a i r a n d m e d i c al
attention immediately. I f c o n t a c t w i t h s k i n o r c l o t h e s i s m a d e , f l u sh
w i t h l a r g e a m o u n t s o f w a t e r .
If contact with eyes is made, wash eyes
with water and get medical aid immediately.
(1)
Clean all parts using cleaning solvent P-D-680; dry using clean cloths.
( 2 ) I n s p e c t f a n a s s e m b l y ( 3 ) f o r b r o k e n , b e n t , o r c r a c k e d b l a d e s ; r e p l a c e i f
n e c e s s a r y .
INSTALLATION
(1) Position fan assembly (3) on water pump assembly
four lock washers (2) and capscrews (l). Tighten
l b - f t .
(2) Position fan shroud on radiator and secure using
capscrews.
( 3 ) I n s t a l l e n g i n e s i d e p a n e l s ( p a g e 9 - 1 7 ).
pulley. Secure using
c a p s c r e w s t o 3 5 t o 4 2
six lock washers and
4-101
(4-102 blank)