TM 5-3805-262-207-3. AIR BRAKE SYSTEM MAINTENANCE (CONT)f. H o s e s , L i n e s, a n d F i t t i n g s ( c o n t ).(2) Replacement (cont).CLEANINGCompressed air used for cleaning purposes will not exceed 30 psi. Useo n l y w i t h e f f e c t i v e c h i p g u a r d i n g a n d p e r s o n a l p r o t e c t i v e e q u i p m e nt( g o g g l e s / s h i e l d , g l o v e s , e t c ).F a i l u r e t o d o s o c o u l d c a u s e s e r i o usi n j u r y t o e y e s a n d p o s s i b l e b l i n d n e s s.If you hurt your eyes or if af o r e i g n o b j e c t i s b l o w n i n t o y o u r e y e s , s e e k m e d i c a l a t t e n t i o nimmediately.(a) Clean hoses (1, 8, 17, 18, 37, 40, 45, 48, and 50) and tubes (26 and 36)using clean cloths moistened with detergent. Clear obstructions frominside hoses using compressed air.Dry cleaning solvent P-D-680 used to clean parts is toxic and flammable.W e a r p r o t e c t i v e g o g g l e s a n d g l o v e s a n d u s e o n l y i n a w e l l v e n t i l a t eda r e a . A v o i d c o n t a c t w i t h s k i n , e y e s a n d c l o t h e s a n d d o n ’ t b r e a t h evapors. Do not use near open flame or excessive heat and don’t smokewhen using it. Failure to do so could cause serious injury. If you be-c o m e d i z z y w h i l e u s i n g c l e a n i n g s o l v e n t , g e t f r e s h a i r a n d m e d i c ala t t e n t i o n i m m e d i a t e l y .If contact with skin or clothes is made, flushwith large amounts of water.I f c o n t a c t w i t h e y e s i s m a d e , w a s h e y eswith water and get medical aid immediately.(b) Clean remaining parts using cleaning solvent P-D-680. Dry using com-pressed air or clean cloths.7-80