TM 5-3805-290-23-2
RADIATOR AND FAN GROUP REPLACEMENT - CONTINUED
0168 00
CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to do so may
result in injury or death to personnel.
1.
Clean all parts and surfaces with solvent cleaning compound.
2.
Inspect all parts for damage, wear, pitting, cracks, or corrosion and replace if necessary.
INSTALLATION
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during pro-
cedure. Ensure any lifting equipment used is in good condition and of suitable load capacity. Keep clear of
heavy parts supported only by lifting equipment. Failure to follow this warning may result in injury or
death to personnel.
N OT E
Radiator and fan group weighs 750 lb (340 kg).
1.
With assistance, attach lifting equipment to fan group (2). Position fan group on machine.
2.
Install washer (70) and bolt (69) on machine.
3.
With assistance, install nut (68), two washers (66), rubber battery clamp (67), and bolt (65) on each side of machine.
RIGHT
427-B0083
427-B0081
0168 00-14