TM 5-3805-291-23-2
PILOT OIL ACCUMULATOR MAINTENANCE - CONTINUED
0150 00
REMOVAL
WARN I N G
When servicing this machine, performing maintenance, or disposing of materials such as engine cool-
ant, hydraulic fluid, lubricants, battery acids or batteries, and CARC paint, consult your unit/local
hazardous waste disposal center or safety office for local regulatory guidance. If further information is
needed, please contact The Army Environmental Hotline at 1-800-872-3845.
DO NOT disconnect or remove any hydraulic system line or fitting unless engine is shut down and
hydraulic system pressure has been relieved. Tighten all connections before applying pressure.
Escaping hydraulic fluid under pressure can penetrate the skin, causing injury to personnel.
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before disconnecting any
hydraulic lines. Failure to follow this warning may result in injury to personnel.
Hydraulic oils used in performance of maintenance can be very slippery. Immediately wipe up any
spills. Failure to follow this warning may result in injury to personnel.
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during pro-
cedure. Ensure that any lifting equipment used is in good condition and of suitable load capacity. Keep
clear of heavy parts supported only by lifting equipment. Failure to follow this warning may result in injury
or death to personnel.
N OT E
Stand capacity must be 5,200 lb (2,359 kg).
1.
Raise lift arms (1) and support with stand assembly.
427-C0596
0150 00-2