BRAKING AND HYDRAULIC FAN PUMP REPLACEMENT - CONTINUED
BRAKING AND HYDRAULIC FAN PUMP REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1114    1115    1116    1117    1118  1119  1120    1121    1122    1123    1124  
img
TM 5-3805-291-23-2
BRAKING AND HYDRAULIC FAN PUMP REPLACEMENT - CONTINUED
0215 00
REMOVAL - CONTINUED
10.
Remove three bolts (24) and washers (25) from piston pump (15). Remove piston pump from machine.
11.
Remove three fittings (26) from piston pump (15). Remove four O-rings (27) from fittings. Discard O-rings.
427-C0593
427-C0592
CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to do so may
result in injury or death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Make
sure air stream is directed away from user and other personnel in the area. To prevent injury, user
must wear protective goggles or face shield. Failure to follow this warning may result in injury to per-
sonnel.
1.
Scrape all gasket material from mating surfaces and clean with solvent cleaning compound.
2.
Dry parts with compressed air.
3.
Inspect all parts for wear, pitting, cracks, or corrosion and replace if necessary.
4.
Inspect oil passages to ensure they are clean and unobstructed.
0215 00-6


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.