REFRIGERANT HOSES, LINES, VALVES, FLANGES, AND FITTINGS REPLACEMENT - CONTINUED
REFRIGERANT HOSES, LINES, VALVES, FLANGES, AND FITTINGS REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1172    1173    1174    1175    1176  1177  1178    1179    1180    1181    1182  
img
TM 5-3805-291-23-2
REFRIGERANT HOSES, LINES, VALVES, FLANGES,
AND FITTINGS REPLACEMENT - CONTINUED
0223 00
INSTALLATION - CONTINUED
9.
Position hoses (35 and 33) in cab.
10.
Install clips (46 and 45) on hoses (35 and 33).
11.
Install washer (44) and bolt (43) on clips (46 and 45).
12.
Install clip (42) on hoses (35 and 33).
13.
Install bolt (39), two washers (38), spacer (40), and nut (37) on clip (41).
14.
Connect hose (35) to hose (36).
15.
Connect hose (33) to hose (34).