Table 1. Torque Limits - SAE Standard Fasteners.
Table 3. 37 Degree Flare Fitting.

Field Maintenance Manual For M400T And M400W
Page Navigation
  1157    1158    1159    1160    1161  1162  1163    1164    1165    1166    1167  
img
TM 5-3805-292-23
0174
GENERAL CONTINUED
Table 2. Torque Limits - Metric Fasteners.
TORQUE VALUES FOR METRIC THREAD FASTENERS WITH LUBRICATED* OR PLATED THREADS†
Thread
Diameter - Pitch
Class 8.8 Bolt
Class 10.9 Bolt
Class 10 Nut
Class 8 Nut
Torque: lb-ft (Nm)
Torque: lb-ft (Nm)
M6
5 (7)
7 (9)
M8
12 (16)
17 (23)
M8 x 1
13 (18)
18 (24)
M10
24 (33)
34 (46)
M10 x 1.25
27 (37)
38 (52)
M12
42 (57)
60 (81)
M12 x 1.5
43 (58)
62 (84)
M14
66 (89)
95 (129)
M14 x 1.5
72 (98)
103 (140)
M16
103 (140)
148 (201)
M16 x 1.5
110 (149)
157 (213)
M18
147 (199)
203 (275)
M18 x 1.5
165 (224)
229 (310)
M20
208 (282)
288 (390)
M20 x 1.5
213 (313)
320 (434)
M22
283 (384)
392 (531)
M22 x 1.5
315 (427)
431 (584)
M24
360 (488)
498 (675)
M24 x 2
392 (531)
542 (735)
M27
527 (715)
729 (988)
M27 x 2
569 (771)
788 (1,068)
M30
715 (969)
990 (1,342)
M30 x 2
792 (1,074)
1,096 (1,486)
* All plated and unplated fasteners should be coated with oil before installation.
† Use these torque values if either the bolt or nut is lubricated or plated (zinc-phosphate conversion-coated,
cadmium-plated, or waxed).