TM 5-3805-298-23-1
0038
Table 1. Engine Is Hard to Start When Cold - Continued.
038
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Cable OK - Replace glow plug relay
4. Inspect glow plug relay magnetic
Engine Is Hard to Start
magnetic switch (Figure 13, Item 2)
switch voltage supply cable
When Cold - Continued
(WP 0261).
(Figure 13, Item 3) for damage and
evidence of short to ground.
Connect all wiring harness connectors.
Install glow plug start aid fuse.
Install left engine access panel
(WP 0350).
Proceed to Test Step 8.
Cable Damaged or Shorted - Replace
glow plug relay magnetic switch voltage
supply cable (Figure 13, Item 3)
between glow plug relay magnetic
switch (Figure 13, Item 2) and fuse
module (Figure 13, Item 1).
Connect all wiring harness connectors.
Install glow plug start aid fuse.
Install left engine access panel
(WP 0350).
Proceed to Test Step 8.
0038-20