Table 1. 1797 Fuel Rail Pressure Sensor Diagnostic Codes - Continued.
065
CID FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1797-3 Fuel Rail Pressure
Test Step 2. Test for Shorted Engine
Sensor Signal Voltage Is
Control Wiring Harness.
1. Turn ignition switch and battery
Above Normal or the
disconnect switch to OFF position
Voltage Is Shorted High -
(TM 5-3805-298-10).
Continued
2. Remove right engine access panel
(WP 0348).
3. Disconnect connector E-C2
pressure sensor.
4. Disconnect connector E-C4
ECM connector J2.
(WP 0174), test for continuity
wiring harness (WP 0294).
between connector E-C4
Proceed to Test Step 4.
and all other E-C4 terminals.
Test Step 3. Test for Open Engine
Control Wiring Harness.
1. Connect jumper wire between
terminal 3 and terminal 2 of
Figure 31).
(WP 0174), measure resistance
Replace fuel rail pressure sensor
between connector E-C4
(WP 0244).
Proceed to Test Step 4.
and terminal 40.
Replace engine control wiring harness
(WP 0294).
Proceed to Test Step 4.
Test Step 4. Verify Malfunction Is
Resolved.
1. Ensure all harness connectors are
connected.
2. Install right engine access panel
(WP 0348).