TM 5-3805-298-23-2
0131
Table 1. Front and Rear Turn Signals Do Not Operate in Either Left or Right Positions,
Stoplights Operate Normally - Continued.
0131
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Front and Rear Turn Signals
4. Observe operation of front and
Left Turn Signals Operate in the
Do Not Operate in Either Left
rear left turn signals (TM 5-3805-
Front and Rear Proceed to step 5.
or Right Positions,
298-10).
Left Turn Signals Do Not Operate
Stoplights Operate Normally
5. Turn the turn signal switch to right
Proceed to step 7.
- Continued
turn signal position (TM 5-3805-
298-10).
6. Observe operation of front and
Right Turn Signals Operate in the
rear right turn signals (TM 5-3805-
Front and Rear Proceed to Test
298-10).
Step 25.
Right Turn Signals Do Not Operate
Proceed to step 10.
7. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
8. Remove lamps fuse from fuse
panel (TM 5-3805-298-10).
lamps fuse (WP 0012, Figure 44,
Item 8).
between terminals of lamps fuse.
Proceed to Test Step 25.
Proceed to Test Step 13.
10. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
11. Remove lamps fuse from fuse
panel (TM 5-3805-298-10).
Resistance 5.0 Ohms or Less
Proceed to Test Step 25.
between terminals of lamps fuse.
Proceed to Test Step 21.
Test Step 13. Test for Shorted Wiring
Harness.
1. Remove blackout turn flash relay
from fuse panel (TM 5-3805-298-
10).
Continuity Proceed to Test Step 14.
No Continuity Proceed to Test
between connector C-C31
Step 16.
(WP 0012, Figure 74) terminal F3
and terminal F2.
0131-7