TM 5-3805-298-23-2
0147
Table 1. All Implements Will Not Operate or Operate Slowly Continued.
0147
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
All Implements Will Not
Test Step 7. Verify Malfunction Is
Operate or Operate Slowly -
Resolved.
Continued
1. Turn ignition switch and battery
disconnect switch to OFF position
(TM 5-3805-298-10).
2. Ensure all hydraulic hoses are
connected.
3. Install main control valve cover
(WP 0371).
4. Turn battery disconnect switch to
ON position and start engine
(TM 5-3805-298-10).
5. Warm the transmission oil to
normal operating temperature of
approximately 165F to 185F
(75C to 85C).
6. Bring the hydraulic oil to operating
temperature of 140F (60C)
(TM 5-3805-298-10).
7. Operate all implements
All Implements Operate Normally
(TM 5-3805-298-10).
Troubleshooting complete.
All Implements Do Not Operate
Repeat troubleshooting from the
beginning.
END OF WORK PACKAGE
0147-6