LO 5-3805-219-12-1
See note 3
See note 2
FOLD
FOLD
-KEY-
EXPECTED TEMPERATURES
LUBRICANTS
CAPACITY
INTERVALS
Above +32 F
+ 40 F to -10 F
0 F to -65 F
OE-OIL, Engine, Heavy Duty
19 qts.
OE 30
OE 10
OES
Oil Can Points
Intervals
Transmission, Converter and Cooler Oil
given are
25 qts.
System
OES
in hours of
OES-OIL, Engine, Sub-zero
normal
OE 10
OE 10
operation.
Hydraulic System
112 qts.
OHA
OHA-HYDRAULIC FLUID, Petroleum
GAA-GREASE, Automotive and Artillery
ALL TEMPERATURES
NOTES:
1. FOR OPERATION OF EQUIPMENT in PROTRACTED COLD
5. ANEROID CONTROL. Every 250 hours , remove breather and fill plug.
Clean and reinstall.
TEMPERATURES BELOW -10F. Remove lubricants prescribed in the key
for temperatures above-10 F. Relubricate with lubricants specified in the key
Copy of this Lubrication Order will remain with the equipment at all times;
for temperatures below -10 F.
instructions contained herein are mandatory.
2. ENGINE OIL FILTER. Every 100 hours , remove filter element clean
BY ORDER OF THE SECRETARY OF THE ARMY:
housing, install new element. Fill crankcase, operate engine 5 minutes,
W. C. WESTMORELAND
check for leaks, check level and bring to full mark.
General, United States Army,
Chief of Staff.
3. TRANSMISSION, CONVERTER AND COOLER, OIL SYSTEM OIL
OFFICIAL:
FILTER. Every 500 hours, remove and clean filter element and housing.
KENNETH G. WICKHAM,
Every 1000 hours, remove element, clean housing, install new element. Fill
Major General United States Army,
system, operate engine 5 minutes, check for leaks, check level and bring to
The Adjutant General
full mark.
4. OIL CAN POINTS. Every 10 hours, lubricate all control linkage and
exposed threads with OE.
LO 5-3805-219-12-1 DISTRIBUTION: To be distributed in accordance
with DA Form 12-25, Section II, (qty rqr block No. 402) Organizational
maintenance requirements for Earth Moving: Loaders.
U.S. GOVERNMENT PRINTING OFFICE: 1984-420-903/2