NOTES - CONTINUED:
W h e n AOAP laboratory support is not
available, install new filter element each
1000 hours.
9. HYDRAULIC OIL FILTER. Each 250
hours, remove element, clean filter hous-
ing a n d i n s t a l l n e w e l e m e n t . A f t e r
r e p l a c e m e n t , operate hydraulic system
for 5 minutes, check for leaks, check level
and bring to "FULL" mark.
10. FRONT PLANETARY/REAR
P L A N E T A R Y . Each 100 hours rotate
wheels to bring level plug horizontal with
center line of axle. Remove plug, check
level, fill and install plug. Change gear
lubricant only when required by
m a i n t e n a n c e repair action, contamina-
tion by water, or other foreign material.
To drain, rotate wheels to bring plug to
bottom center, remove plug and drain.
Rotate wheels back to level point, fill and
i n s t a l l plug. After refill, operate for 5
minutes, check for leaks, and bring oil
level to fill plug opening.
11. FRONT DIFFERENTIAL/REAR DIF-
FERENTIAL. Check level each 100 hours.
Change gear lubricant only when required
Copy of this Lubrication Order will remain
by maintenance repair action, contamina-
with the equipment at all times, instruc-
tion by water, or other foreign material.
tions contained herein are mandatory.
After refill, operate for 5 minutes, check
for leaks and bring oil level to fill plug
By order of the Secretary of the Army:
opening.
JOHN A. WICKHAM, JR.
General, United States Army
Chief of Staff
applicable specification numbers.
OFFICIAL:
OE/HDO
MIL-L-2104
MIL-L-2105
GO
ROBERT M. JOYCE
MIL-L-46167
OEA
Major General, United States Army
GAA
MIL-G-10924
The Adjutant General
P-D-680
(SD), Type II
DISTRIBUTION:
To be distributed in accordance with
12-256, Operator and
DA Form
O r g a n i z a t i o n a l maintenance re-
quirements for Scoop-Type Loader.
TA 219609
CARD 6 OF 6