PLAN VIEW
- KEY -
LUBRICANTS
CAPACITY
EXPECINTED TEMPERATURES
INTERVALS
Above -+32F
+40F to -10F
0F to -65F
OE -OIL, Engine, Heavy Duty
Crankcase
18 qt
OE 30
OE 10
OES
Oil Can Points
OES -OIL, Engine, Sub-zero
FOLD
FOLD
GO LUBRICATING OIL, Gear
Front Axle Planetary
6 qt ea
Intervals
Rear Axle Planetary
5 qt ea
GO 90
GO 90
GOS
given are
GOS -LUBRICATING OIL, Gear, Sub-zero
in hours
HBA -FLUID, Hydraulic, Non-petroleum
of normal
Brake Power Cluster
ALL TEMPERATURES
operation.
GAA -GREASE, Automotive and Artillery
NOTES:
1.
FOR OPERATION OF EQUIPMENT IN PROTRACTED COLD
6. AXLE PLANETARIES. Every 50 hours rotate wheels until oil level line is
horizontal. Check level. Every 1000 hours rotate wheels until drain and fill
TEMPERATURES BELOW-10 F. Remove lubricants prescribed in the key
plug is at bottom center, remove plug, and drain. To fill, rotate wheels until oil
for temperatures above-10 F. Relubricate with lubricants specified in the key
level is horizontal, and fill to plug opening.
for temperatures below-10F.
7. LUBRICANTS. The following is a list of lubricants with the Military
2. ENGINE OIL FILTERS. Every 100 hours remove filter elements, clean
Symbols and applicable specifications numbers.
housings, install new elements, fill crankcase, operate engine for 5 minutes,
check for leaks, check crankcase oil level and bring to full mark.
GO-MIL-L-2105
GOS-MIL-L-1 0324
GAA-MIL-G-10924
HBA-MIL-H-1 3910
3. HYDRAULIC RESERVOIR OIL FILTER. After first 50 hours of operation,
remove hand hole cover from top of hydraulic tank, remove and clean filter,
Copy of this Lubrication Order will remain with the equipment at all times;
service every 500 hours thereafter. Let oil cool before servicing.
instructions contained herein are mandatory.
4. OIL CAN POINTS. Every 50 hours lubricate control linkage, and all
BY ORDER OF THE SECRETARY OF THE ARMY:
exposed adjusting threads with OE.
HAROLD K. JOHNSON
OFFICIAL:
General, United States Army,
5. TRANSMISSION AND CONVERTER OIL FILTER. Every 500 hours
KENNETH G. WICKHAM
Chief of Staff.
remove filter element, clean housing, install new element, fill system, operate
Major General, United States Army,
equipment for 5 minutes, check for leaks. Check transmission oil level and
The Adjutant General.
bring to full mark.
LO 5-3805-243-12-1 DISTRIBUTION: TO be distributed in accordance with DA Form 12-25, Section
II, Organizational Maintenance requirements for Earth Moving Equipment Loaders.
U.S. GOVERNMENT PRINTING OFFICE : 1984 O - 426-388