TM 5-2420-231-23-1
0022
Table 1. Transmission Temperature Gauge Indicates High Temperature,
Does Not Function, or Is Inaccurate - Continued.
022
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Verify that transmission tempera-
Transmission Temperature
Transmission Temperature Gauge
near or Below Lowest Mark - Proceed
ture gauge (Figure 2, Item 1) is
Gauge Indicates High
within lowest and highest marks
to Test Step 4.
Temperature, Does Not
(TM 5-2420-231-10).
Function, or Is Inaccurate -
Transmission Temperature Gauge
Above Highest Mark - Proceed to Test
Continued
Step 6.
Transmission Temperature Gauge
Within Lowest and Highest Marks -
Proceed to step 4.
CAUTION
Do not allow the machine to become overheated during this procedure. If
the transmission temperature gauge indicates high temperature, turn
ignition switch off immediately, or damage may result.
4. Start and operate machine (TM 5-
2420-231-10) for approximately 10
minutes.
5. Monitor and record transmission
Transmission Temperature Gauge
temperature (Figure 2, Item 1) (TM
Indicates High Temperature -
5-2420-231-10).
Proceed to Test Step 3.
Transmission Temperature Gauge
Does Not Move or Remains Within
Lowest and Highest Marks - Proceed
to Test Step 4.
Figure 2. Transmission Temperature Gauge.
0022