TM 5-2420-231-23-1
0051
Table 1. Transmission Does Not Shift into Forward - Continued.
051
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Transmission Does Not Shift
continuity between powershift con-
front cover (WP 0174).
into Forward - Continued
troller wiring harness connector
Replace powershift wiring harness (WP
0167).
and all other terminals on harness.
Proceed to Test Step 38.
There should be no continuity.
front cover (WP 0174).
Replace transmission controller (WP
0168).
Connect powershift wiring harness
Install front floor cover plate (WP 0306).
Proceed to Test Step 38.
Test Step 20. Test Directional
Ground Circuit for an Open.
1. Remove front floor cover plate
(WP 0306).
2. Disconnect powershift wiring har-
Figure 147).
Resistance 5.0 Ohms or Less -
sure resistance between power-
Proceed to step 4.
shift controller wiring harness
Install instrument panel front cover (WP
terminal D1 and powershift wiring
0174).
Replace powershift wiring harness (WP
ure 146) terminal D. Resistance
0167).
should be 5.0 ohms or less.
Proceed to Test Step 38.
Resistance 5.0 Ohms or Less -
sure resistance between power-
Proceed to step 5.
shift controller wiring harness
Install instrument panel front cover (WP
terminal E1 and powershift wiring
0174).
harness connector terminal B (WP
Replace powershift wiring harness (WP
0007, Figure 146). Resistance
0167).
should be 5.0 ohms or less.
Proceed to Test Step 38.
Resistance 5.0 Ohms or Less -
sure resistance between power-
Proceed to step 6.
shift controller wiring harness
Install instrument panel front cover (WP
terminal F1 and powershift wiring
0174).
harness connector terminal C (WP
Replace powershift wiring harness (WP
0007, Figure 146). Resistance
0167).
should be 5.0 ohms or less.
Proceed to Test Step 38.
0051-24