Table 1. Transmission Does Not Shift into Forward - Continued.
Table 1. Transmission Does Not Shift into Forward - Continued.

Tractor, Wheeled, Industrial Backhoe Loader Nsn 2420-01-532-3399
Page Navigation
  740    741    742    743    744  745  746    747    748    749    750  
img
. . . . . . . . . . .
TM 5-2420-231-23-1
0051
Table 1. Transmission Does Not Shift into Forward - Continued.
051
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Transmission Does Not Shift
Test Step 31. Test Shift Lever
into Forward - Continued
Forward Voltage Supply Circuit for
Voltage.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Disconnect powershift controller
wiring harness connector (WP
0007, Figure 21) from powershift
lever (WP 0007, Figure 114).
3. Connect batteries (WP 0157) and
turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
4. Using a digital multimeter, mea-
Voltage 10 to 14 Volts - Proceed to
sure voltage between front console
Test Step 32.
wiring harness connector (WP
No Voltage - Replace powershift lever
0007, Figure 185) terminal 85 and
(WP 0165).
machine ground. There should be
Proceed to Test Step 38.
no voltage.
Test Step 32. Test Front Console
Wiring Harness Forward Relay
Voltage Supply Circuit.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Disconnect powershift wiring har-
ness connector (WP 0007, Figure
113) from front console wiring har-
ness connector (WP 0007, Figure
112).
3. Using a digital multimeter, test for
Continuity - Replace front console
continuity between front console
wiring harness (WP 0162).
wiring harness connector (WP
Proceed to Test Step 38.
0007, Figure 112) terminals C and
No Continuity - Install instrument panel
D. There should be no continuity.
front cover (WP 0174).
Replace powershift wiring harness (WP
0167).
Proceed to Test Step 38.
Test Step 33. Test Forward Control
Circuit for a Short.
1. Using a digital multimeter, mea-
Voltage 10 to 14 Volts - Proceed to
sure voltage between powershift
step 2.
controller wiring harness connec-
No Voltage - Install instrument panel
tor (WP 0007, Figure 20) terminal
front cover (WP 0174).
C2 and machine ground. There
Replace forward relay (WP 0007,
should be no voltage.
Figure 186) (WP 0162).
Proceed to Test Step 38.
0051-39