TM 5-2420-231-23-1
0052
Table 1. Transmission Does Not Shift into Reverse - Continued.
052
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Voltage 24 to 28.5 Volts - Proceed to
5. With engine still running, monitor
Transmission Does Not Shift
step 6.
and record voltage on digital multi-
into Reverse - Continued
meter. Voltage should be 24 to
Voltage Greater Than 28.5 Volts -
28.5 volts.
Proceed to Test Step 38.
0052
6. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10).