TM 5-2420-231-23-1
0052
Table 1. Transmission Does Not Shift into Reverse - Continued.
052
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Voltage 10 to 14 Volts - Proceed to
Transmission Does Not Shift
sure voltage between powershift
Test Step 30.
into Reverse - Continued
controller wiring harness connec-
No Voltage - Proceed to step 8.
C2 and machine ground. Monitor
and record voltage. There should
be no voltage present.
Voltage 10 to 14 Volts - Proceed to
sure voltage between powershift
Test Step 34.
controller wiring harness connec-
No Voltage - Install instrument panel
front cover (WP 0174).
D2 and machine ground. Monitor
Replace transmission controller (WP
and record voltage. There should
0168).
be no voltage present.
Connect powershift wiring harness
Install front floor cover plate (WP 0306).
Proceed to Test Step 38.
Test Step 30. Test Forward Relay Coil
Voltage Supply Circuit for Voltage.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
Figure 186) from front console wir-
Figure 185).
3. Connect batteries (WP 0157) and
turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
Voltage 10 to 14 Volts - Proceed to
sure voltage between front console
Test Step 31.
wiring harness connector (WP
No Voltage - Proceed to Test Step 33.
0007, Figure 185) terminal 85 and
machine ground. There should be
no voltage.
Test Step 31. Test Shift Lever
Forward Voltage Supply Circuit for
Voltage.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Disconnect powershift controller
wiring harness connector (WP
0007, Figure 21) from powershift
0052-38