TM 5-2420-231-23-1
0052
Table 1. Transmission Does Not Shift into Reverse - Continued.
052
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Voltage 10 to 14 Volts - Proceed to
Transmission Does Not Shift
sure voltage between front console
Test Step 35.
into Reverse - Continued
wiring harness connector (WP
No Voltage - Proceed to Test Step 37.
0007, Figure 105) terminal 85 and
machine ground. There should be
no voltage.
Test Step 35. Test Shift Lever
Forward Voltage Supply Circuit for
Voltage.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Disconnect powershift controller
wiring harness connector (WP
0007, Figure 21) from powershift
3. Connect batteries (WP 0157) and
turn ignition switch to the on posi-
tion (TM 5-2420-231-10).
Voltage 10 to 14 Volts - Proceed to
sure voltage between front console
Test Step 36.
wiring harness connector (WP
No Voltage - Install instrument panel
0007, Figure 105) terminal 85 and
front cover (WP 0174).
machine ground. There should be
Replace powershift lever (WP 0165).
no voltage.
Proceed to Test Step 38.
Test Step 36. Test Front Console
Wiring Harness Forward Relay
Voltage Supply Circuit.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Disconnect powershift wiring har-
113) from front console wiring har-
112).
continuity between front console
wiring harness (WP 0162).
wiring harness connector (WP
Proceed to Test Step 38.
0007, Figure 112) terminals A and
D. There should be no continuity.
wiring harness (WP 0167).
Proceed to Test Step 38.
0052-41