TM 5-2420-231-23-1
0060
Table 1. Engine Does Not Turn Off With Ignition Switch in the Off Position
and Machine Does Not Move - Continued.
060
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Engine Does Not Turn Off
continuity between powershift con-
With Ignition Switch in the
harness (WP 0167).
nector wiring harness connector
Off Position and Machine
Proceed to Test Step 3.
Does Not Move - Continued
No Continuity - Replace transmission
and all other terminals on harness.
controller (WP 0168).
There should be no continuity.
Connect powershift wiring harness
Proceed to Test Step 5.
Test Step 3. Test Output 2 Control
Circuit for a Short to Voltage.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Disconnect powershift wiring har-
Figure 147).
continuity between powershift con-
harness (WP 0167).
nector wiring harness connector
Proceed to Test Step 4.
No Continuity - Replace transmission
and all other terminals on harness
controller (WP 0168).
connector. There should be no
Connect powershift wiring harness
continuity.
Proceed to Test Step 5.
Test Step 4. Test Output 8 Control
Circuit for a Short to Voltage.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Disconnect powershift wiring
Figure 146) from transmission (WP
continuity between powershift con-
harness (WP 0167).
nector wiring harness connector
Proceed to Test Step 5.
No Continuity - Replace transmission
and all other terminals on harness.
controller (WP 0168).
There should be no continuity.
Connect powershift wiring harness
Proceed to Test Step 5.
0060-4