Table 1. Backhoe Auxiliary Hydraulic Control Does Not Operate Correctly - Continued.
081
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 6. Test Pilot Control Flow.
Backhoe Auxiliary Hydraulic
Control Does Not Operate
Perform pilot control valve test (WP
Pilot Control Flow Greater Than 1
Correctly - Continued
gpm - Perform Flowmeter Disconnect
Replace backhoe control valve
assembly (WP 0263).
Proceed to Test Step 14.
Pilot Control Flow Less Than 1 gpm
- Perform Flowmeter Disconnect
Replace pilot control valve assembly
(WP 0264).
Proceed to Test Step 14.
Test Step 7. Test Pilot Control Wiring
Harness for a Short to Ground.
1. Ensure ignition switch is in the off
position (TM 5-2420-231-10) and
disconnect batteries (WP 0157).
2. Disconnect pilot control wiring har-
160) from pilot control controller
(WP 0187).
3. Remove left tower boot (WP
0287).
4. Disconnect pilot control wiring har-
219) from LH tower wiring harness
continuity between pilot control
wiring harness (WP 0187).
wiring harness connector (WP
Proceed to Test Step 14.
0007, Figure 219) terminal 5 and
No Continuity - Proceed tostep 6.
terminal 3. There should be no
continuity.
continuity between pilot control
wiring harness (WP 0187).
wiring harness connector (WP
Proceed to Test Step 14.
0007, Figure 219) terminal 5 and
No Continuity - Proceed to step 7.
terminal 4. There should be no
continuity.
continuity between pilot control
wiring harness (WP 0187).
wiring harness connector (WP
Proceed to Test Step 14.
0007, Figure 219) terminal 5 and
No Continuity - Proceed to step 8.
machine ground. There should be
no continuity.
0081-9