TM 5-2420-231-23-1
0081
Table 1. Backhoe Auxiliary Hydraulic Control Does Not Operate Correctly - Continued.
081
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Backhoe Auxiliary Hydraulic
Resistance 5.0 Ohms or Less -
sure resistance between pilot con-
Proceed to step 6.
Control Does Not Operate
trol wiring harness connector (WP
Correctly - Continued
0007, Figure 219) terminals 3 and
Replace pilot controls wiring harness
machine ground. Resistance
(WP 0187).
should be 5.0 ohms or less.
Proceed to Test Step 14.
Resistance 5.0 Ohms or Less -
sure resistance between pilot con-
Proceed to step 7.
trol wiring harness connector (WP
0007, Figure 219) terminals 4 and
Replace pilot controls wiring harness
machine ground. Resistance
(WP 0187).
should be 5.0 ohms or less.
Proceed to Test Step 14.
Resistance 5.0 Ohms or Less -
sure resistance between pilot con-
Proceed to step 8.
trol wiring harness connector (W)
0007, Figure 219) terminal 1 and
Replace pilot controls wiring harness
terminal 2. Resistance should be
(WP 0187).
5.0 ohms or less.
Proceed to Test Step 14.
Resistance 5.0 Ohms or Less -
sure resistance between pilot con-
Replace auxiliary control switches (WP
trol wiring harness connector (WP
0266).
0007, Figure 219) terminal 2 and
Connect all wiring harness connectors.
pilot control wiring harness con-
Proceed to Test Step 14.
minals 16. Resistance should be
Replace pilot controls wiring harness
5.0 ohms or less.
(WP 0187).
Proceed to Test Step 14.
Test Step 9. Test Pilot Control Wiring
Harness for a Short to Voltage.
1. Turn ignition switch to the off posi-
tion (TM 5-2420-231-10) and dis-
connect batteries (WP 0157).
2. Disconnect pilot control wiring har-
160) from pilot control controller.
3. Remove left tower boot (WP
0287).
4. Disconnect pilot control wiring har-
219) from LH tower wiring harness
continuity between pilot control
wiring harness (WP 0187).
wiring harness connector (WP
Proceed to Test Step 14.
0007, Figure 219) terminals 1 and
5. There should be no continuity.
0081-11