Figure 31. Fan Guard.
SLAVE STARTING THE LOADER

Maintenance Manual For Loader, Scoop Type, Ded 4 X 4, Articulated Frame Steer, 4.5 To 5 Cu. Yd.
Page Navigation
  82    83    84    85    86  87  88    89    90    91    92  
img
. . . . .
10
TM 5-3805-255-14
0006
OPERATOR MAINTENANCE
-
OPERATION UNDER UNUSUAL CONDITIONS
0006
Slave Starting the Loader, Operation in Extreme Cold, Operation in Extreme Heat, Operation in Saltwater
Areas, Operation in Mud or Soft Surfaces, Operation in Sandy or Dusty Conditions, Operation at High
Altitudes, Operation in Snow and Ice
INITIAL SETUP
References
References - Continued
0
0
FM 3-3
FM 31-71
0
0
FM 3-3-1
FM 90-3
0
0
FM 9-20
WP 0005
0
0
FM 21-305
WP 0011
0
0
FM 31-70
WP 0013
0
0
WP 0018
0
INTRODUCTION
0006
1. This work package contains instructions for safely operating the H100C Loader under unusual conditions.
2. In addition to normal preventive maintenance, special care must be taken to keep the loader operational in
extreme temperatures and other environmental conditions.
SLAVE STARTING THE LOADER
0006
WARNING
When slave starting loader:
Use NATO slave cable that does NOT have loose or missing insulation.
DO NOT proceed if suitable cable is not available.
DO NOT use civilian-type jumper cables.
DO NOT allow "dead" and "live" machines to come in contact with each other at any time
during slave starting.
Failure to follow these warnings may cause injury or death to personnel, or damage to
equipment.
0006-1