TM 5-3805-258-24-19 5 0 B O P E R A T O R ’ S S T A T I O NE L E C T R I C A L T R O U B L E S H O O T I N G2. Disconnect the B/W wire from the terminal of the test switch. Check forcontinuity across terminals of the test switch. Use an 8S4627 Circuit Tester andhold the switch in the TEST position.ContinuityNo ContinuityGo to Step 3.Replace the test switch.3. Check for continuity from the wire still connected to the Test switch tomachine ground.ContinuityNo ContinuityRepair or replace the harness.Repair or replace the harness or connect a wire fromthe terminal of the test switch to machine ground.PROBLEM C: ALL Indicators Are ON; Master Fault Light is OFF.Possible Causes: a. The light bulb is bad.b. The harness to the master fault light is bad.c. The operator panel is bad.TROUBLESHOOTING1. Remove the red lens and the master fault light bulb. With a 5P7277 VoltageTester, check the master fault light receptacle for voltage (All switches still inTEST I position).VoltageNo VoltageMake a replacement of the bulb.2. Remove the Y/LT BL wirereceptacle. Check the wires forswitch in TEST position).VoltageGo to Step 2.and the B wire from the master fault lightvoltage with a 5P7277 Voltage Tester (TestNo VoltageReplace the light bulb receptacle and make sureGo to Step 3.wires are connected tightly.3. Check for voltage between the Y/LT BL wire and machine ground with the5P7277 Voltage Tester. (Test Switch in TEST position.)VoltageNo VoltageGround wire is broken. Repair or replace harness orGo to Step 4.make a ground from receptacle connection to ma-chine.4-105