TM 5-3805-262-203-12. SENDING UNITS TROUBLESHOOTING (CONT) MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION3. WATER TEMPERATURE SENDING UNIT DOES NOT OPERATE.Remove and test water temperature sending unit (page 5-120).a .b.If water temperature sending unit tests okay, reinstall sendingunit (page 5-123) and refer to page 3-80, MALFUNCTION 11.If water temperature gage and wiring are okay, refer to page3-53 cooling system troubleshooting.If water temperature sending unit does not test okay, replacesending unit (page 5-120).4. CONVERTER TEMPERATURE SENDING UNIT DOES NOT OPERATE.Remove and test converter temperature sending unit (page 5-125).a . I f c o n v e r t e r t e m p e r a t u r e s e n d i n g u n i t t e s t s o k a y , r e i n s t a llsending unit (page 5-127) and refer to page 3-79, MALFUNCTION 1.If converter temperature gage and wiring are okay, refer to page3-101 transmission troubleshooting.b. If converter temperature sending unit does not test okay, re -place sending unit (page 5-125).5. CLUTCH PRESSURE SWITCH DOES NOT OPERATE.Step 1. Remove engine right front sidepanel (page 9-14).Disconnect wire leads fromterminals of clutch pressureswitch by grasping with fingersand firmly pulling apart.Connect multimeter between clutchpressure switch terminals.Multimeter should indicate continuity.a . I f m u l t i m e t e r i n d i c a t e s c o n t i n u -ity, go to step 2 below.b. If multimeter does not indicatec o n t i n u i t y , r e p l a c e c l u t c h p r e s-sure switch (page 5-128).Step 2. Start engine and watch multimeter.Multimeter should indicate no continuity (open circuit).3-94