3-30. ENGINE TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. ENGINE STARTS BUT WILL NOT RUN (Cont).
S t e p 7 . ( C o n t ) .
NOTE
Be sure batteries are at full charge. Dont do more than two compression
unbalance tests in a row as loader batteries may discharge .
Check that fuel SHUT OFF control is pulled completely out.
Crank engine for five seconds to clear fuel from cylinders.
Set VTM TEST SELECT switches to 14.
NOTE
While cranking engine with bad or discharged batteries, VTM may lose
power and come on again after cranking has stopped, displaying -----. If
this happens, clean battery posts and clamps and try again. If VTM still
loses power, connect VTM to another vehicles battery. Connect P1 of
test probe cable W2 to J4 of VTM and W2 black test clip to loader bat-
t e r y n e g a t i v e p o s t a n d r e d t e s t c l i p t o l o a d e r b a t t e r y p o s i t i v e p o s t.
Then set VTM TEST SELECT switches to 15.
Press and release TEST.
When GO appears on display, crank engine until OFF or E013 appears
on display. Be sure to return ignition key switch to off position .
Display should indicate (TBD).
a .
b .
c .
d .
e .
If display indicates (TBD), compression unbalance is okay. Go to
step 8 below.
If display indicates a number higher
higher maintenance level (additional
If FAIL is displayed, compression is
than (TBD), notify next
tests must be performed).
too far unbalanced to be
measured using STE/ICE. Notify next higher maintenance level
(additional tests must be performed).
If GO appears, repeat this step.
If E013 is displayed, test data cannot be analyzed due to weak
batteries or interrupted cranking during test. Correct weak bat-
teries by charging them, then repeat this step. If E013 message
persists, after two tests, notify next higher maintenance level
to perform compression test using pressure gage.