TM 5-3805-262-203-30. ENGINE TROUBLESHOOTING (CONT)MALFUNCTIONTEST OR INSPECTIONCORRECTIVE ACTION6. ENGINE STALLS FREQUENTLY OR DOES NOT DEVELOP FULL POWER (Cont).S t e p 6 . ( C o n t ).Dry cleaning solvent P-D-680 used to cleanp a r t s i s t o x i c a n d f l a m m a b l e . W e a rprotective goggles and gloves and use onlyi n a w e l l v e n t i l a t e d a r e a . A v o i d c o n t a ctw i t h s k i n , e y e s a n d c l o t h e s a n d d o n ’ tbreathe vapors. Do not use near open flameo r e x c e s s i v e h e a t a n d d o n ’ t s m o k e w h enu s i n g i t . F a i l u r e t o d o s o c o u l d c a u ses e r i o u s i n j u r y.If you become dizzy whileu s i n g c l e a n i n g s o l v e n t , g e t f r e s h a i r a ndm e d i c a l a t t e n t i o n i m m e d i a t e l y . I f c o n t a ctw i t h s k i n o r c l o t h e s i s m a d e , f l u s h w i thl a r g e a m o u n t s o f w a t e r . I f c o n t a c t w i t heyes is made, wash eyes with water and getmedical aid immediately.D i r t o r o t h e r f o r e i g n m a t t e r c a n d a m a gefuel injection pump and fuel injectors andc a u s e e n g i n e s t a r t i n g p r o b l e m s . D i r t a ndf o r e i g n m a t t e r c a n e n t e r f u e l l i n e s w h enyou disconnect them. To prevent this fromh a p p e n i n g , c l e a n a l l f i t t i n g s , p l u g s , a n df u e l l i n e c o n n e c t i o n s b e f o r e b r e a k i n gc o n n e c t i o n s u s i n g c l e a n c l o t h s m o i s t e n edwith cleaning solvent P-D-680.Remove plug from elbow installed in fuel injection pump.3-228