AIR CONDITIONING HOSES, VALVES, FLANGES, FITTINGS, AND ACCUMULATOR REPLACEMENT
AIR CONDITIONING HOSES, VALVES, FLANGES, FITTINGS, AND ACCUMULATOR REPLACEMENT - CONTINUED

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  1106    1107    1108    1109    1110  1111  1112    1113    1114    1115    1116  
img
TM 5-3805-290-23-2
AIR CONDITIONING HOSES, VALVES, FLANGES, FITTINGS,
AND ACCUMULATOR REPLACEMENT - CONTINUED
0193 00
REMOVAL
C AU T I O N
Wipe area clean around all connections to be opened during removal. Cap lines and hoses and plug
openings after removing lines. Contamination of system could result in premature failure.
N OT E
Tag hoses prior to removal to ensure correct installation.
Use a container to catch any fluid that may drain from hoses or system. Dispose of fluids IAW local pol-
icy and ordinances. Ensure all spills are cleaned up.
Inline refrigerant dryer MUST be replaced anytime the AC system is opened.
1.
Disconnect hoses (1 and 2) from refrigerant accumulator (3). Remove and discard O-rings (4 and 5) from hoses.
427-B1070
0193 00-2