QUICK COUPLER REPLACEMENT - CONTINUED
QUICK COUPLER REPLACEMENT - CONTINUED

Manual 2 Loader, Light, Scoop: 2.5 Cubic Yard Multipurpose (Mp) Clamshell Bucket, Diesel Engine Driven (Ded), 4-Wheel Drive Model 924G
Page Navigation
  1142    1143    1144    1145    1146  1147  1148    1149    1150    1151    1152  
img
TM 5-3805-290-23-2
QUICK COUPLER REPLACEMENT - CONTINUED
0198 00
CLEANING AND INSPECTION
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low-toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to do so may
result in injury or death to personnel.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Make sure
air stream is directed away from user and other personnel in the area. To prevent injury, user must
wear protective goggles or face shield. Failure to follow this warning may result in injury to personnel.
1.
Clean all parts and surfaces with solvent cleaning compound.
2.
Dry parts with compressed air.
3.
Inspect all parts for damage, wear, pitting, cracks, or corrosion and replace if necessary.
INSTALLATION
N OT E
Apply a thin coat of clean oil to all O-rings before installation.
1.
Install two new lip seals (16) on lever assembly (15).
2.
Apply grease to all pin bores and lip seals.
427-B0664
0198 00-7