TM 5-3805-291-10
Messenger Reference Guide
Calibrations: Lever Calibrations Screen
The following lever calibrations can be performed using this sub menu:
Lift Lever calibration
Tilt Lever calibration
Third Function Lever calibration
Step Number
Step and Display String
1.
Press next button to start
2.
Set parking brake
3.
Engage implement lockout switch
4.
Place lift lever in HOLD. `Next'
5.
Place lift lever in full RAISE. `Next'
6.
Place lift lever in full LOWER. `Next'
0004 00-48