TM 5-3805-291-10
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
INCLUDING LUBRICATION INSTRUCTIONS - CONTINUED
0012 00
Table 1. Preventive Maintenance Checks and Services (PMCS) for the 966H Wheel Loader - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
15
Before
Ether Starting
Aid System
0012 00
WARN I N G
Ether fuel is extremely flammable and toxic. DO NOT
smoke and make sure you are in a well-ventilated area
away from heat, open flames or sparks. Wear eye protec-
tion. Avoid contact with skin and eyes and avoid breathing
ether fumes. If fluid enters or fumes irritate the eyes, wash
immediately with large quantities of clean water for 15
minutes. Seek medical attention immediately if ether is
inhaled or causes eye irritation. Failure to follow this warn-
ing may cause serious injury or death to personnel.
N OT E
Ether canister needs to be installed when starting
below 40F (4C).
If canister is not installed, ensure cap is installed on
a. Check that ether canister is present Ether canister or cap is
and securely installed.
missing.
REAR AND
RIGHT SIDE
Check on ground under machine for Class III oil or coolant leaks
16
Before
Overall View
evidence of fluid leakage such as oil, are evident. Any fuel leak-
age is evident.
coolant, or fuel.
a. Check that rear lights are present Rear lights are missing or
17
Before
Rear of
damaged, if required for
and not damaged.
Machine
mission.
b. Open rear access door.
c. Ensure fuel tank filler cap is Fuel tank filler cap is miss-
ing.
installed.
d. Check for evidence of any fuel Any fuel leaks are evident.
leaks.
e. Close rear access door.
Rear access door will not
close and latch securely.
0012 00-8