TM 5-3805-291-23-1
ELECTRICAL SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0013 00
STARTING MOTOR TEST - CONTINUED
Hold-in Winding Test
1.
Refer to illustration in order to make connections to
solenoid. Disconnect all other leads to solenoid.
2.
battery load tester to adjust battery voltage until volt-
age is 20V.
3.
Observe reading on clamp-on ammeter.
6.8 amperes should be observed.
N OT E
A high reading indicates a shorted
winding. A low reading indicates exces-
4.
The hold-in winding can also be checked by measur-
ing resistance. Disconnect batteries. Select "200 Ω"
range on multimeter. Connect one of the leads of mul-
timeter to "S" terminal and connect other lead to "G"
terminal. 2.9 Ω minimum should be observed.
427-C1984
5.
Replace starter (WP 0051 00) if any of the above read-
ings are incorrect.
0013 00-77