STARTING MOTOR TEST - CONTINUED
STARTING MOTOR TEST - CONTINUED

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  891    892    893    894    895  896  897    898    899    900    901  
img
TM 5-3805-291-23-1
ELECTRICAL SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0013 00
STARTING MOTOR TEST - CONTINUED
Hold-in Winding Test
1.
Refer to illustration in order to make connections to
solenoid. Disconnect all other leads to solenoid.
2.
Close switch. Observe reading on multimeter. Use
battery load tester to adjust battery voltage until volt-
age is 20V.
3.
Observe reading on clamp-on ammeter.
6.8 amperes should be observed.
N OT E
A high reading indicates a shorted
winding. A low reading indicates exces-
sive resistance.
4.
The hold-in winding can also be checked by measur-
ing resistance. Disconnect batteries. Select "200 Ω"
range on multimeter. Connect one of the leads of mul-
timeter to "S" terminal and connect other lead to "G"
terminal. 2.9 Ω minimum should be observed.
427-C1984
5.
Replace starter (WP 0051 00) if any of the above read-
ings are incorrect.
0013 00-77