AIR CONDITIONING SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
REFRIGERANT QUICK-CHECK PROCEDURE FOR R-134A EXPANSION VALVE AND ORIFICE TUBE SYSTEMS

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1078    1079    1080    1081    1082  1083  1084    1085    1086    1087    1088  
img
TM 5-3805-291-23-1
AIR CONDITIONING SYSTEM TESTS, INSPECTIONS, AND ADJUSTMENTS - CONTINUED
0018 00
A loss of cooling ability of system and failure of compressor may be caused by one or more of the following conditions:
Low charge.
Overcharge.
Too much oil.
Too little oil.
Dirty filter or plugged filter.
Dirty condenser or plugged condenser.
Dirty evaporator or plugged evaporator.
Dirty orifice tube or plugged orifice tube.
Dirty expansion valve or plugged expansion valve.
Too much moisture in system.
Missing drain valves for evaporator.
0018 00-4