GENERAL PMCS PROCEDURES
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) INCLUDING LUBRICATION INSTRUCTIONS

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1099    1100    1101    1102    1103  1104  1105    1106    1107    1108    1109  
img
TM 5-3805-291-23-1
PREVENTIVE MAINTENANCE CHECKS AND SERVICES
(PMCS) INTRODUCTION - CONTINUED
0019 00
GENERAL PMCS PROCEDURES - CONTINUED
C AU T I O N
Operation is allowable with Class I and Class II leakage, EXCEPT for fuel, where NO leaks are allowed.
WHEN IN DOUBT, NOTIFY YOUR SUPERVISOR. When operating with Class I or Class II leaks, check
fluid levels more frequently. Class III leaks must be reported immediately to your supervisor. Failure to do
this will result in damage to machine and/or components.
N OT E
Notify your supervisor of any leaks you cannot fix.
Leakage Definitions for Unit PMCS
Class I
Leakage indicated by wetness or discoloration, but not great enough to form
drops.
Class II
Leakage great enough to form drops, but not enough to cause drops to drip from
the item being checked/inspected.
Class III
Leakage great enough to form drops that fall from the item being checked/
inspected.
END OF WORK PACKAGE