• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AIR CLEANER AND PRECLEANER REPLACEMENT - CONTINUED
Air Cleaner and Precleaner - Continued

Field Maintenance Manual 1 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  1193    1194    1195    1196    1197  1198  1199    1200    1201    1202    1203  
img
TM 5-3805-291-23-1
AIR CLEANER AND PRECLEANER REPLACEMENT - CONTINUED
0030 00
INSTALLATION
CAU T I ON
Replace secondary filter element when primary filter element is serviced for a third time. Always replace
secondary filter element. DO NOT attempt to reuse it by cleaning. Engine damage could result. If a clean
primary filter element has been installed and a warning for the air filter still occurs, replace the secondary
filter element. Also, if exhaust smoke remains black and a clean primary filter element has been installed,
replace secondary filter element.
Air Filter Elements
1.
Install secondary filter element (29) in air cleaner
housing (24).
2.
Install primary filter element (28) in air cleaner hous-
ing (24).
3.
Install cover (27) on air cleaner housing (24).
427-C0186
Air Cleaner and Precleaner
1.
Install air cleaner housing (24) on air cleaner assembly
(10).
2.
Install four washers (26) and bolts (25) on air cleaner
assembly (10).
3.
Install precleaner assembly (20) on air cleaner housing
(24).
4.
Install three washers (22), bolts (21), and nuts (23) on
air cleaner assembly (10).
5.
Tighten clamp (19) on precleaner assembly (20).
427-C0155