LIFT KICKOUT POSITION SENSOR AND MOUNTING REPLACEMENT - CONTINUED
LIFT KICKOUT POSITION SENSOR AND MOUNTING REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  170    171    172    173    174  175  176    177    178    179    180  
img
TM 5-3805-291-23-2
LIFT KICKOUT POSITION SENSOR AND MOUNTING REPLACEMENT - CONTINUED
0085 00
REMOVAL - CONTINUED
8.
Remove wiring harness (12) from clip (13).
9.
Remove two bolts (14), washers (15), and plate (16) from rod end (17).
10.
Remove five bolts (18), washers (19 and 20), and nuts (21) from bracket (7).
11.
Remove tilt position sensor (22) from bracket (7).
427-C0286
0085 00-3