FAN HYDRAULIC MOTOR AND FAN GROUP REPLACEMENT - CONTINUED
FAN HYDRAULIC MOTOR AND FAN GROUP REPLACEMENT - CONTINUED

Field Maintenance Manual 2 For Loader, Heavy, Scoop: Diesel Engine Driven (Ded), 4-Wheel Drive 4.5 Cubic Yard Rock Bucket And 5.0 Cubic Yard General Purpose Bucket
Page Navigation
  896    897    898    899    900  901  902    903    904    905    906  
img
TM 5-3805-291-23-2
FAN HYDRAULIC MOTOR AND FAN GROUP REPLACEMENT - CONTINUED
0192 00
REMOVAL - CONTINUED
WARN I N G
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during pro-
cedure. Ensure that any lifting equipment used is in good condition and of suitable load capacity. Keep
clear of heavy parts supported only by lifting equipment. Failure to follow this warning may result in injury
or death to personnel.
N OT E
Fan group weighs 255 lb (116 kg).
6.
With assistance, remove four bolts (15) and washers
(16) from both sides of fan group (14).
427-C0370
N OT E
Position fan group on cribbing.
7.
Remove four bolts (17) and washers (18) from shield
(19).
427-C0371