Figure 16. Hydraulic Reservoir Filler Cap, Radiator Drain Valve, and Sight Gauge.
Figure 18. Radiator Overflow Tank.

Operators Manual For M400T And M400W
Page Navigation
  153    154    155    156    157  158  159    160    161    162    163  
img
.
TM 5-3805-292-10
0020
Table 1. Preventive Maintenance Checks and Services (PMCS)
for the M400T and M400W SSL - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT READY/
NO.
INTERVAL
HOURS
PROCEDURE
AVAILABLE IF:
SERVICE
Before
0.1
Hydraulic
c. If oil is not visible in sight gauge, Oil is not visible.
19
(Cont)
Reservoir
add oil until visible at midpoint in
sight gauge.
CAUTION
When servicing hydraulic reservoir, clean filler cap and area around filler cap to help reduce the risk of
hydraulic system contamination. Failure to follow this caution can result in damage to equipment.
1. Check cap is present.
Cap is missing.
2. Clean filler cap and area
around filler cap with a rag.
3. Slowly turn filler cap
counterclockwise (left) until
pressure is relieved, then
remove filler cap.
4. Add oil through filler opening
until oil level is visible at
midpoint in sight gauge.
Refer to LO 5-3805-292-13
for correct grade of oil for
expected temperature range.
5. Install filler cap and turn fully
clockwise (right) until tight.
HYDRAULIC RESERVOIR
FILLER CAP
SIGHT
GAUGE
RADIATOR DRAIN VALVE
458-0882
Figure 17. Hydraulic Reservoir Filler Cap and Sight Gauge.
0020
0020-18