• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 1. Oil Pump Tube.
Figure 3. Oil Pump.

Field Maintenance Manual For M400T And M400W
Page Navigation
  286    287    288    289    290  291  292    293    294    295    296  
img
.
TM 5-3805-292-23
0034
REMOVAL CONTINUED
2. Remove three bolts (Figure 2, Item 1) and oil pump (Figure 2, Item 3) from engine (Figure 2, Item 2).
Figure 2. Oil Pump.
0034
END OF TASK
CLEANING AND INSPECTION
00034
1. Remove all gasket material from mating surfaces.
WARN I N G
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and
low toxic material. However, it may be irritating to the eyes and skin. Use protective gloves
and goggles. Use in well-ventilated areas. Keep away from open flames and other
sources of ignition. Failure follow this warning may result in injury or death to personnel.
2. Clean all parts (except rubber and plastic surfaces) and mating surfaces with solvent cleaning compound.
WARN I N G
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa)
nozzle pressure when drying parts with compressed air. DO NOT direct compressed air
against human skin. Make sure air stream is directed away from user and other personnel
in the area. To prevent injury, user must wear protective goggles or face shield. Failure to
follow this warning may result in injury to personnel.
3. Dry parts with compressed air.
4. Inspect parts for wear, pitting, cracks, or corrosion and replace if necessary.
END OF TASK
0034-3


Privacy Statement
Press Release
Contact