TM 5-3805-292-23
0066
INSTALLATION
00066
WARN I N G
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in well ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury or death to personnel.
N OT E
Install lines and fittings as tagged during removal.
1. Install three hydraulic fittings (Figure 4, Item 7) and lines (Figure 4, Item 6) on hydraulic drive motor (Figure 4,
Item 1).
2. Install clamp (Figure 4, Item 2) and hose (Figure 4, Item 8) on hydraulic drive motor (Figure 4, Item 1).
3. Install lifting device on hydraulic drive motor (Figure 4, Item 1).
WARN I N G
Use assistance when lifting heavy parts. Failure to follow this warning may result in injury
to personnel.
N OT E
Hydraulic drive motorweighs 130 lb (59 kg).
Orient hydraulic drive motor as noted during removal.
4. Apply sealing compound to bolts and mating surfaces before installing.
5. With assistance, attach lifting device and install hydraulic drive motor (Figure 4, Item 1), six washers (Figure 4,
Item 3), bolts (Figure 4, Item 4), and nuts (Figure 4, Item 9) on machine.
6. Torque six bolts (Figure 4, Item 4) and nuts (Figure 4, Item 9) to 90 lb-ft (122 Nm).
7. Torque six bolts (Figure 4, Item 4) and nuts (Figure 4, Item 9) an additional 60 degrees.
8. Remove lifting device from hydraulic drive motor (Figure 4, Item 1).
9. Connect hydraulic line (Figure 4, Item 5) to hydraulic drive motor (Figure 4, Item 1).
0066-4