TANDEM PUMP REPLACEMENT
Figure 1. Tandem Pump.

Field Maintenance Manual For M400T And M400W
Page Navigation
  474    475    476    477    478  479  480    481    482    483    484  
img
TM 5-3805-292-23
0068
WARN I N G
When servicing this machine, performing maintenance, or disposing of hazardous
materials, consult your unit/local hazardous waste disposal center or safety office for local
regulatory guidance. If further information is needed, please contact The Army
Environmental Hotline at 1-800-872-3845.
DO NOT disconnect or remove any hydraulic sysem lines or fitting unless engine is shut
t
down and hydraulic system pressure has been relieved. Tighten all connections before
applying pressure. Escaping hydraulic fluid under pressure can penetrate the skin.
At operating temperature, hydraulic oil is hot. Allow hydraulic oil to cool before removing
any hydraulic fitting.
To prevent injury to personnel, wear protective eye covering and gloves.
Failure to follow these warnings may result in injury or death to personnel.
C AU T I O N
Cap all hydraulic hose and line ends along with component connections during removal to
protect against contamination. Failure to follow this caution may result in damage to
equipment.
N OT E
Tag all hoses and linesto aid in installation.
Use a container to catch any fluid that maydrain from hoses or system. Dispose of fluid
IAW local policy and ordinances. Ensure all spills are cleaned up.